The APx555 is a two-channel audio analyzer which is recognized as the standard of the audio industry. With a typical residual THD+N of -120 dB and over 1 MHz bandwidth, the APx555 surpasses the analog performance of all other audio analyzers, including a 5 dB improvement compared to the 2700 Series analyzer. Add to this FFTs of 1.2 million points and full 24-bit resolution, and you have performance unmatched by any other instrument.
APx555 has two balanced and two unbalanced analog inputs and outputs plus 216k digital inputs and outputs via AES/EBU, TOSLINK and SPDIF. Additionally, I/O may be expanded with optional Digital Serial, HDMI with ARC, PDM and Bluetooth modules.
SYSTEM REQUIREMENTS:
Microsoft Windows 10 (64-bit) operating system.
USB 2.0 or USB 3.0. Two are required for optional switcher or DCX-127 use.
Intel i5 or better processor running at a clock speed of at least 2.5 GHz. AMD processors with similar specifications are also supported.
At least 8 GB RAM. 16 GB is highly recommended internet connection or CD-ROM drive (to access APx500 software for installation).
At least 1.5 GB of free hard disk space. An SSD for the operating system drive is recommended.
A color monitor and video card with at least SXGA (1280 X 1024) video graphics support. Video resolution of 1900 x 1080 or greater is recommended.
GENERATOR PERFORMANCE | Sine Frequency Range | 0.001 Hz to 80 kHz, DAC 5 Hz to 204 kHz, Analog |
Frequency Accuracy | 3 ppm, DAC 30 ppm, Analog (Precision Tune) | |
IMD Test Signals | SMPTE, MOD, DFD, DIM | |
Maximum Amplitude (balanced) | 26.66 Vrms | |
Amplitude Accuracy | ±0.03 dB | |
Flatness (5 Hz–20 kHz) | ±0.008 dB | |
Residual THD+N (22 kHz BW) | –117 dB + 1.0 µV Typically < –120 dB (1 kHz, 2.0 V) | |
Analog Output Configurations | unbalanced, balanced (differential & single-ended), CMTST | |
Digital Output Sampling Rate | 27 kS/s to 200 kS/s 27 kS/s to 108 kS/s Optical | |
ADC Test VBias Range | –0.4 to +4.2 VDC | |
ANALYZER PERFORMANCE | Maximum Rated Input Voltage | 230 Vpk |
Maximum Bandwidth | > 1 MHz | |
IMD Measurement Capability | SMPTE, MOD, DFD, DIM | |
Amplitude Accuracy (1 kHz) | ±0.03 dB | |
Amplitude Flatness (10 Hz–20 kHz) | ±0.008 dB | |
Residual Input Noise (22 kHz BW) | 1.0 µV | |
Residual THD+N (22 kHz BW) | –117 dB + 1.0 µV Typically < –120 dB (1 kHz, 2.0 V) | |
Individual Harmonic Analyzer | H2–H10 | |
Max FFT Length | 1248K points | |
DC Voltage Measurement | Yes |